TM-1402 Series Progressive Scan Shutter Cameras
Page 25
Operation
3.10 Camera Timing Charts
Model: TM-1402 Operation Mode: 30 Frame /sec
Master Clock: 100 MHz, M=10 nsec
Pixel Clock: 50 MHz, P= 20 nsecec
1. Pixel Clock and Digital Data
Tcd
TdcT hd
Tcd: Clock to Data Ready
Tdc: Data Ready to Next Clock
Thd: Data Hold Time
Pixel Clock
Data
A
Tcc =14 nsec, Tdc = 6 nsec, Thd = 5 nsec.
2. Horizontal Signals
External HD
Internal HD
LDV
Digital Data
Analog Video
fHD = [ 31.09KHz]
tHD = [ 32.16 µs]
B [ 1608 P], (32.16 µs)
A [ 1447 P], (28.94 µs)
F [ 1608 P], (32.16µs)
E [ 1392 P], (27.84 µs)
D [ 216 P], (4.32 µs)
H [ 216 P], (4.32 µs)
G [ 1392 P], (27.84 µs)
J [ 168P], ( 3.36 µs)
K [ 1392 P], (27.84 µs)
L [ 61 P], (1.22µs)
I [ 48 P], (960 ns)
C [12 P], (240 µs)
[ 3 P], (60 ns)