Page 21
Operation
TMC-6700/1000 Series Progressive Scan CCD Digital Color Camera
FIGURE 10. External Pulse Width Control
3.5.2 (b) Long Integration
With pulse-width control, long integration is possible up to a few seconds besides integration control
(pin #11 of the 12-pin connector).
3.5.2 (c) Internal Fast Reset Mode (1H~8H, or 1/16,000~1/2,000)
When fast reset mode is selected, the camera resets with internal VINIT timing which is latched to H
D.
Video output is also synchronized with internal VINIT timing without further delay. The shutter speed
is controlled by the shutter dial.
3.5.2 (d) Internal Slow Reset Mode (9H~1048H, or >1/2,000~1/15)
With the Internal Slow Reset mode selected, the camera operates the reset and shutter by the same
means as the wide pulse width control mode. When external VINIT pulse is applied, internal VINIT is
latched to H
D and the second internal VINIT signal is generated to set up the shutter speed period.
Video output timing starts right after the second internal VINIT.
9H
X
External
Pulse
Width
Hd
Internal Vinit
Transfer Gate
Pulse
Discharge
pulse
Composite
Video
Exposure Time
18H
(min. 1H)