Page 50
VIS CAM 300/400 Installation Manual
Appendix A: Camera Functional and Connector Description
5.3.1 Functionality
Output to flash unit. This output is used when only one flash unit is connected. The output is
galvanically isolated using an optocoupler. The isolated part of the electronics on the board can be
powered from the flash unit or from the I/O Board using a 24V DC output on the connector.
5.3.2 Connector specification
Connector type: 6 pole WAGO pluggable terminal block
Connector on board: WAGO 734-236
Cable part: WAGO 734-206
5.3.3 Connector signal specifications
Description
Logic inverter powered by 5V drives the output. The inverter is a HCMOS type 74AHC14.
Output signal specification
Signal amplitude 5V TTL
Output impedance 100 Ω
Pulse width 5 ms ± 1 ms
Signal polarity active high
External power requirement
Voltage 8-26V DC
Current max 25μA