VIS CAM 300/400 Installation Manual
Appendix A: Camera Functional and Connector Description
5.8 Cables
In order to comply with EMC regulations the cable must be shielded and the wires must be twisted
pairs. The cable used for the Ethernet signals must be minimum Cat 5e and preferably Cat 6.
The wires used for power must be a minimum 0.5 mm
2
.
5.8.1 Cable Specifications
5.8.1 (a) Ethernet:
Category Cat 5e or preferably Cat 6
Characteristic impedance 100 Ω
Number of twisted pairs 4
Maximum cable diameter 15 mm
Maximum cable length 100 meters
5.8.1 (b) RS485 and power:
Characteristic impedance 120 Ω
Number of twisted pairs 4
Wire dimension 0.5mm
2
Maximum cable diameter 15 mm
Maximum cable length 100 meters
5.8.2 Recommended Cables
Ethernet: Cable, Cat 6 S-FTP 4x2xAWG24 JAI No. 2900.00.262
Power and RS485: Cable Twisted Pair 4x2x0.5mm
2
JAI No. 2900.00.267
Combined cable Cat 6, RS485 and power: JAI No. 2900.00.268
5.8.3 Mounting the cables
Please refer to Section 3 on page 15 of this manual.
Zobrazit stránku 77